NoFossil Control System Web Interface

Home Physical I/O Data Elements Rules Logs System
Sensor Inputs
0 SI Barn2house supply 103.6
0 SI 500g tank middle 160.6
0 SI 500g tank top 165.6
0 SI 500g tank bottom157.9
0 SI wood boiler supply167.6
0 SI wood boiler return158.7
0 SI bottom 250G tank162.6
0 SI top 250G tank161.3
0 SI gassification chamber79.4
0 SI flue at boiler exit143.5
0 SI inside barn 92.8
0 SI Barn2house return151.7
0 SI Domestic tank130.4
0 SI 500G Tank return120.9
0 SI 500G Tank supply114.9
0 SI INCUBATOR82.0

Analog Outputs
0 AO Barn2House circ0.0
0 AO TankHeat source-circ0.0
0 AO Wood-boiler-circ0.0
0 AO Not used0.0

 
Discrete Inputs
0 User Switch DownFalse
0 User Switch UpFalse
0 DI VikingBio Pellet Burner swtchFalse
0 DI Barn input 2False
0 DI Barn input 3False
0 DI Barn input 4False
0 DI Taco control end switchFalse
0 DI-06-P03-C0202False
0 DI-07-P03-C0203False
0 DI-08-P03-C0204False

Discrete Outputs
0 LED1 Wood-1 Pellet-2 Tank-5 Lp-0True
0 LED2 Storage levelFalse
0 LED3 Barn2House Circ ONFalse
0 LED 4False
0 DO not usedFalse
0 DO barn2house circ relayFalse
0 DO Domestic circFalse
0 DO Wood/Pellets-T LP-FTrue
0 DO barn relay1False
0 DO barn relay2False
0 DO barn relay3False
0 DO pellet burnerFalse

 
Variables
0 145 deg145.0
0 5 deg5.0
0 40 deg40.0
0 Pellet is hot1.0
0 Barn2House circ start tmp160.0
0 Zero0.0
0 10 deg10.0
0 15 deg15.0
0 2 deg2.0
0 Storage Heat Source1.0
0 Domestic W/Wood0.0
0 500G Tank Hot1.0
0 Lowest usable tank temp125.0
0 Return ^ than Supply0.0
0 170 deg170.0
0 WoodBoiler start circ180.0
0 Tank needs heat0.0
0 Stop wood circ1.0
0 BoilerReturn too Low0.0
0 Domestic W/Propane0.0
0 Fire is burning0.0
0 Low speed47.0
0 High speed80.0
0 3 deg3.0
0 WoodBoilerIsHot-run-low0.0
0 WoodBoiler ^ than 500G bot1.0
0 WoodBoiler circ on1.0
0 20 deg20.0
0 Medium speed50.0
0 WoodBoilerIsHot-run-medium0.0
0 WoodBoilerIsHot-run-high0.0
0 Minimum speed42.0
0 WoodBoilerIsHot-run-minium0.0
0 30 deg30.0
0 Wood hotter than 500g top0.0
0 Tank circ low0.0
0 Tank circ high0.0
0 Tank circ medium0.0
0 190 deg190.0
0 Tank circ minimum0.0
0 Idle speed41.0
0 Tank circ idle0.0
0 Flash LED 11.0
0 Flash LED 22.0
0 1 deg1.0
0 OVERHEAT0.0
0 Flash LED 52.9

Differential Rules
Set Tank needs heat if SI 500g tank top is at least Zeroless than170 degwith a deadband of 30 deg
Set Domestic W/Wood if SI Domestic tankis at least Zeroless thanLowest usable tank tempwith a deadband of 20 deg
Set Storage Heat Source if SI 500g tank top is at least Lowest usable tank tempgreater thanZerowith a deadband of 2 deg
Set Domestic W/Propane if SI Domestic tankis at least Zeroless thanLowest usable tank tempwith a deadband of 20 deg
Set WoodBoilerIsHot-run-minium if SI wood boiler supplyis at least Zerogreater thanWoodBoiler start circwith a deadband of 10 deg
Set WoodBoilerIsHot-run-low if SI wood boiler supplyis at least 15 deggreater thanWoodBoiler start circwith a deadband of 5 deg
Set WoodBoilerIsHot-run-medium if SI wood boiler supplyis at least 30 deggreater thanWoodBoiler start circwith a deadband of 5 deg
Set WoodBoilerIsHot-run-high if SI wood boiler supplyis at least 40 deggreater thanWoodBoiler start circwith a deadband of 5 deg
Set WoodBoiler ^ than 500G bot if SI wood boiler supplyis at least 5 deggreater thanSI 500g tank bottomwith a deadband of 2 deg
Set BoilerReturn too Low if SI wood boiler returnis at least Zeroless than145 degwith a deadband of 10 deg
Set Return ^ than Supply if SI wood boiler returnis at least Zerogreater thanSI wood boiler supplywith a deadband of 2 deg
Set Wood hotter than 500g top if SI wood boiler supplyis at least 10 deggreater thanSI 500g tank top with a deadband of 5 deg
Set Fire is burning if SI flue at boiler exitis at least 40 deggreater thanWoodBoiler start circwith a deadband of 5 deg
Set Pellet is hot if SI wood boiler supplyis at least Zerogreater than170 degwith a deadband of 15 deg
Set Tank circ minimum if SI 500G Tank supplyis at least 5 deggreater thanSI 500G Tank returnwith a deadband of 2 deg
Set Tank circ low if SI 500G Tank supplyis at least 15 deggreater thanSI 500G Tank returnwith a deadband of 2 deg
Set Tank circ medium if SI 500G Tank supplyis at least 20 deggreater thanSI 500G Tank returnwith a deadband of 2 deg
Set Tank circ high if SI 500G Tank supplyis at least 30 deggreater thanSI 500G Tank returnwith a deadband of 2 deg
Set Tank circ idle if SI 500G Tank supplyis at least Zerogreater thanSI 500G Tank returnwith a deadband of 2 deg
Set OVERHEAT if SI wood boiler supplyis at least 40 deggreater than170 degwith a deadband of 5 deg

Logical Rules
Set LED1 Wood-1 Pellet-2 Tank-5 Lp-0 to TRUEif DI VikingBio Pellet Burner swtchis nottrue and WoodBoilerIsHot-run-miniumistrue and DO barn2house circ relayistrue
Set LED1 Wood-1 Pellet-2 Tank-5 Lp-0 to TRUEif WoodBoilerIsHot-run-miniumistrue and Flash LED 1istrue and DI VikingBio Pellet Burner swtchistrue
Set LED1 Wood-1 Pellet-2 Tank-5 Lp-0 to TRUEif Storage Heat Sourceistrue and Flash LED 5istrue and Fire is burningis nottrue
Set DO Wood/Pellets-T LP-F to TRUEif Storage Heat Sourceistrue
Set DO Domestic circ to TRUEif DO Wood/Pellets-T LP-Fis nottrue and Domestic W/Propaneistrue
Set DO Domestic circ to TRUEif DO Wood/Pellets-T LP-Fistrue and Domestic W/Woodistrue
Set AO Barn2House circ to Minimum speedif WoodBoilerIsHot-run-miniumistrue and WoodBoiler ^ than 500G botistrue and DI VikingBio Pellet Burner swtchis nottrue
Set AO Barn2House circ to Medium speedif WoodBoilerIsHot-run-lowistrue and WoodBoiler ^ than 500G botistrue and DI VikingBio Pellet Burner swtchis nottrue
Set AO Barn2House circ to Low speedif WoodBoilerIsHot-run-mediumistrue and WoodBoiler ^ than 500G botistrue and DI VikingBio Pellet Burner swtchis nottrue
Set AO Barn2House circ to Medium speedif WoodBoilerIsHot-run-highistrue and DI VikingBio Pellet Burner swtchis nottrue
Set DO pellet burner to TRUEif Pellet is hotis nottrue and Tank needs heatistrue
Set DO pellet burner to FALSEif Pellet is hotistrue
Set AO Wood-boiler-circ to Minimum speedif WoodBoilerIsHot-run-miniumistrue
Set AO Wood-boiler-circ to Medium speedif WoodBoilerIsHot-run-lowistrue
Set AO Wood-boiler-circ to Medium speedif WoodBoilerIsHot-run-mediumistrue and Fire is burningistrue
Set AO Wood-boiler-circ to High speedif WoodBoilerIsHot-run-highistrue
Set DO barn relay3 to TRUEif DI VikingBio Pellet Burner swtchistrue
Set AO TankHeat source-circ to Minimum speedif DI Taco control end switchistrue and DI VikingBio Pellet Burner swtchis nottrue
Set AO TankHeat source-circ to Low speedif DO Wood/Pellets-T LP-Fistrue and Tank circ lowistrue and DI VikingBio Pellet Burner swtchis nottrue
Set AO TankHeat source-circ to Medium speedif DO Wood/Pellets-T LP-Fistrue and Tank circ mediumistrue and DI VikingBio Pellet Burner swtchis nottrue
Set AO TankHeat source-circ to High speedif DO Wood/Pellets-T LP-Fistrue and Tank circ highistrue and DI VikingBio Pellet Burner swtchis nottrue
Set DO Wood/Pellets-T LP-F to TRUEif DI VikingBio Pellet Burner swtchistrue and WoodBoilerIsHot-run-miniumistrue
Set AO Barn2House circ to High speedif DI Taco control end switchistrue and DI VikingBio Pellet Burner swtchistrue
Set AO Barn2House circ to Minimum speedif Tank circ minimumistrue and DI VikingBio Pellet Burner swtchistrue and DI Taco control end switchistrue
Set AO Barn2House circ to Low speedif Tank circ lowistrue and DI VikingBio Pellet Burner swtchistrue and DI Taco control end switchistrue
Set AO Barn2House circ to Medium speedif Tank circ mediumistrue and DI VikingBio Pellet Burner swtchistrue and DI Taco control end switchistrue
Set AO Barn2House circ to High speedif Tank circ highistrue and DI VikingBio Pellet Burner swtchistrue and DI Taco control end switchistrue
Set DO barn2house circ relay to TRUEif DI VikingBio Pellet Burner swtchistrue and DI Taco control end switchistrue and WoodBoilerIsHot-run-miniumistrue
Set DO barn2house circ relay to TRUEif WoodBoilerIsHot-run-miniumistrue and DI VikingBio Pellet Burner swtchis nottrue and Wood hotter than 500g topistrue
Set LED 4 to TRUEif Fire is burningistrue

Timer Rules
Set Flash LED 1 for 1 deg secondswhen Flash LED 1isfalse
Set Flash LED 2 for 2 deg secondswhen Flash LED 2isfalse
Set Flash LED 5 for 5 deg secondswhen Flash LED 5isfalse